VENTILATOR PA500 Medical Ventilator

PA500 Hospital Patient Ventilator Medical Device

Comprehension at a glance. The built in high visibility LED alphanumeric display offers a simple and convenient method for users to view detailed relevant patient status information in a timely an easily accessible manner.

Dedicated to providing clinical quality mechanical ventilation, the PA500 combines vast ventilation expertise with a non frills user friendly approach.

2,990.00

from 100 pcs.
2,990.00 2,840.50

Available on backorder

PRICE MATCH! If you find a lower price elsewhere we will do our best to price match it.

Your list is empty, add products to the list to send a request

Return to Shop

Cart

Description

Display: LED Display Following Parameters

Operating mode and respiratory rate;

  • Ventilator control frequency set by medical staff;
  • Tidal volume of each breath in the patient;
  • Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
  • Expiratory phase and inspiratory phase and actual respiratory rate;

Ventilator Construction:

  • Environmental Protection Material construction, hardly to be broken.
  • Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Physical specifications
Display LED Display
Mode pneumatically powered and electrically controlled system
Trolley Fitted with 4 nos anti-static rubber castors;

two of which are lockable for braking and easy maneuverability

with foot operated brake provisions

Technical Specifications
Gas requirement Medical oxygen with a pressure ranging from 280~600kpa
safety valve <12.5  kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL
PEEP 0.1 ~ 1.0 kPa
Ptr -4 ~ 10 hPa
IMV frequency 1~12 bpm
I/E Ratio 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume 0-1500ml
Inspiratory Plateau 0~1s
Maximum Safety  Pressure ≤ 6.0kPa
Sigh one deep breath per 80 controlled respirations,

the inspiration time is 1.5 times of the setting point

Pressure limit range 0 ~ 6.0 kPa
Airway pressure alarm Lower: 0.9 kPa ~ 5.4 kPa;   Upper: 0.5  kPa
Audible and visual and with yellow and red color indicating ±0.2 kPa
Ventilation Volume alarm ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm,

the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen

of the anesthetic respirator.

Download PDF Information PA500-Ventilator

Reviews

There are no reviews yet.

Be the first to review “VENTILATOR PA500 Medical Ventilator”

Your email address will not be published. Required fields are marked *

Display: LED Display Following Parameters

Operating mode and respiratory rate;

  • Ventilator control frequency set by medical staff;
  • Tidal volume of each breath in the patient;
  • Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
  • Expiratory phase and inspiratory phase and actual respiratory rate;

Ventilator Construction:

  • Environmental Protection Material construction, hardly to be broken.
  • Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Physical specifications
Display LED Display
Mode pneumatically powered and electrically controlled system
Trolley Fitted with 4 nos anti-static rubber castors;

two of which are lockable for braking and easy maneuverability

with foot operated brake provisions

Technical Specifications
Gas requirement Medical oxygen with a pressure ranging from 280~600kpa
safety valve <12.5  kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL
PEEP 0.1 ~ 1.0 kPa
Ptr -4 ~ 10 hPa
IMV frequency 1~12 bpm
I/E Ratio 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume 0-1500ml
Inspiratory Plateau 0~1s
Maximum Safety  Pressure ≤ 6.0kPa
Sigh one deep breath per 80 controlled respirations,

the inspiration time is 1.5 times of the setting point

Pressure limit range 0 ~ 6.0 kPa
Airway pressure alarm Lower: 0.9 kPa ~ 5.4 kPa;   Upper: 0.5  kPa
Audible and visual and with yellow and red color indicating ±0.2 kPa
Ventilation Volume alarm ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm,

the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen

of the anesthetic respirator.

Download PDF Information PA500-Ventilator

Cart

+351 210 200 144

UK & EU WAREHOUSES
Worldwide Special Flights or by
sea deliveries available on demand.

SEND ENQUIRY
Products - Large Qty Quote
Airlift - Quote for Transport
Become a Distributor
Other

TELEPHONE
Portugal: +351 210 200 144
UK: +44 208 0892 566
Spain: +34 951 82 30 00
USA: + 1 877 405 4999
Canada: + 1 845 201 7666
Iceland: +354 557 1000

Categories

Shop: