VENTILATOR PA500 Medical Ventilator
PA500 Hospital Patient Ventilator Medical Device
Comprehension at a glance. The built in high visibility LED alphanumeric display offers a simple and convenient method for users to view detailed relevant patient status information in a timely an easily accessible manner.
Dedicated to providing clinical quality mechanical ventilation, the PA500 combines vast ventilation expertise with a non frills user friendly approach.
€2,990.00
from 100 pcs. |
---|
PRICE MATCH! If you find a lower price elsewhere we will do our best to price match it.
Description
Display: LED Display Following Parameters
Operating mode and respiratory rate;
- Ventilator control frequency set by medical staff;
- Tidal volume of each breath in the patient;
- Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
- Expiratory phase and inspiratory phase and actual respiratory rate;
Ventilator Construction:
- Environmental Protection Material construction, hardly to be broken.
- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Physical specifications | |
Display | LED Display |
Mode | pneumatically powered and electrically controlled system |
Trolley | Fitted with 4 nos anti-static rubber castors;
two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications | |
Gas requirement | Medical oxygen with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 6~60 times/ min |
Oxygen concentration output | <50% |
minute volume | ≥18L |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL |
PEEP | 0.1 ~ 1.0 kPa |
Ptr | -4 ~ 10 hPa |
IMV frequency | 1~12 bpm |
I/E Ratio | 1:1.5; 1:2.0; 1:2.5; 1:3.0 |
Tidal Volume | 0-1500ml |
Inspiratory Plateau | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh | one deep breath per 80 controlled respirations,
the inspiration time is 1.5 times of the setting point |
Pressure limit range | 0 ~ 6.0 kPa |
Airway pressure alarm | Lower: 0.9 kPa ~ 5.4 kPa; Upper: 0.5 kPa |
Audible and visual and with yellow and red color indicating | ±0.2 kPa |
Ventilation Volume alarm | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm,
the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. |
Display: LED Display Following Parameters
Operating mode and respiratory rate;
- Ventilator control frequency set by medical staff;
- Tidal volume of each breath in the patient;
- Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
- Expiratory phase and inspiratory phase and actual respiratory rate;
Ventilator Construction:
- Environmental Protection Material construction, hardly to be broken.
- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Physical specifications | |
Display | LED Display |
Mode | pneumatically powered and electrically controlled system |
Trolley | Fitted with 4 nos anti-static rubber castors;
two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications | |
Gas requirement | Medical oxygen with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 6~60 times/ min |
Oxygen concentration output | <50% |
minute volume | ≥18L |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL |
PEEP | 0.1 ~ 1.0 kPa |
Ptr | -4 ~ 10 hPa |
IMV frequency | 1~12 bpm |
I/E Ratio | 1:1.5; 1:2.0; 1:2.5; 1:3.0 |
Tidal Volume | 0-1500ml |
Inspiratory Plateau | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh | one deep breath per 80 controlled respirations,
the inspiration time is 1.5 times of the setting point |
Pressure limit range | 0 ~ 6.0 kPa |
Airway pressure alarm | Lower: 0.9 kPa ~ 5.4 kPa; Upper: 0.5 kPa |
Audible and visual and with yellow and red color indicating | ±0.2 kPa |
Ventilation Volume alarm | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm,
the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. |
+351 210 200 144
UK & EU WAREHOUSES
Worldwide Special Flights or by
sea deliveries available on demand.
SEND ENQUIRY
Products - Large Qty Quote
Airlift - Quote for Transport
Become a Distributor
Other
TELEPHONE
Portugal: +351 210 200 144
UK: +44 208 0892 566
Spain: +34 951 82 30 00
USA: + 1 877 405 4999
Canada: + 1 845 201 7666
Iceland: +354 557 1000
Reviews
There are no reviews yet.